Products

SNKQI & SRCQI
Isolated Quad Sink & Source Digital Output Driver Modules

GENERAL DESCRIPTION
The SNKQI and SRCQI are electrically isolated, quad, output drivers that require minimal external components for safe operation from 9V to 65V at continuous load currents up to 350mA. Both devices have a complete microprocessor interface that includes a reset function. The reset guarantees that all outputs will be disabled during power-up.

Isolation for both devices is 2500Vrms for one minute which makes them ideal for applications with high transient voltages and different ground potentials.

The modules come in an encapsulated 40 pin DIP package and are interchangeable.

FEATURES
• Operation to 65V at 350mA
• Minimal External Components
• Microprocessor Interface
• Separate Reset Circuit
• Single +5V Supply
• Operation from -40 °C to +85 °C
• UL and CSA Approval Pending

APPLICATIONS
• Industrial Relay Drive
• High Noise Environments
• Ground Potential Variations

SNKQI OUTPUT STAGE ELECTRICAL CHARACTERISTICS

SYMBOL PARAMETER TEST CONDITIONS MIN MAX UNIT
VBIAS Load Bias Voltage Continuous 9 65 V
VSRC Load Sink Voltage Continuous .2 1.3 V
Isnk (CONT) Continuous Sink Current Continuous - 350 mA
Isnk (PULSE) Pulse Sink Current Pulse Duty - 500 mA
VISO (CONT) Continuous Isolation VRMS for 1 Min 2500 - VRMS
VISO (PEAK) Peak Isolation VRMS for 1 Sec 5000 - VRMS



SRCQI OUTPUT STAGE ELECTRICAL CHARACTERISTICS

SYMBOL PARAMETER TEST CONDITIONS MIN MAX UNIT
VBIAS Load Bias Voltage Continuous 9 65 V
VSRC Load Source Voltage Continuous 7.7 63.7 V
Isrc (CONT) Continuous Source Current Continuous - 350 mA
Isrc (PULSE) Pulse Source Current Pulse Duty - 500 mA
VISO (CONT) Continuous Isolation VRMS for 1 Min 2500 - VRMS
VISO (PEAK) Peak Isolation VRMS for 1 Sec 5000 - VRMS



SNKQI/SRCQI ELECTRICAL PARAMETERS
Maximum Ratings (Maximum Ratings are those values beyond
which damage to the device may occur)

SYMBOL PARAMETER VALUES UNIT
VIN DC Input Voltage (Referenced to GND) -1.5 to VCC + 1.5 V
IIN DC Input Current, per PIN +/- 20 mA
Tstg Storage Temperature -65 to + 150 °C



RECOMMENDED OPERATING CONDITIONS

SYMBOL PARAMETER MIN MAX UNIT
VCC DC Supply Voltage (Referenced to GND) 4.5 6.0 V
TA Operating Temperature - 40 + 85 °C
tr, tf Input Rise and Fall Time
VCC = 4.5
VCC = 6.0

0
0

500
400
ns



INPUT DC ELECTRICAL CHARACTERISTICS
(Voltages Referenced to GND)

GUARANTEED LIMIT
SYMBOL PARAMETER TEST CONDITIONS Vcc
- 40 °C To 25 °C
25 °C To 85 °C
UNIT
VIH Min. High-Level Input Voltage - 4.5
6.0
3.15
4.2
3.15
4.2
V
VIL Max. Low-Level Input Voltage - 4.5
6.0
0.9
1.2
0.9
1.2
V
Iin Max. Input Leakage Current Vin = VCC or GND 6.0 +/- 0.1 +/- 1.0 µA
ICC Max. Quiescent Supply Current Vin = VCC or GND
Iout = 0 µA

6.0

8

80
µA

INPUT AC ELECTRICAL CHARACTERISTICS
(Input tr = tf = 6ns)

GUARANTEED LIMIT
SYMBOL PARAMETER Vcc
- 40 °C To
25 °C
25 °C To
85 °C
UNIT
fmax Maximum Clock Frequency
(50% Duty Cycle)
4.5
6.0
8
8
6
6
KHz
Cin Maximum Input Capacitance - 10 10 pF



TIMING REQUIREMENTS
(Input tr = tf = 6ns)

GUARANTEED LIMIT
SYMBOL PARAMETER VccV - 40 °C To 25 °C 25 °C To 85 °C UNIT
tsu Minimum Setup Time,
Data to Clock
4.5
6.0
20
17
25
21
ns
th Minimum Hold Time,
Clock to Data
4.5
6.0
3
3
3
3
ns
trec Minimum Recovery Time,
Reset Inactive to Clock
4.5
6.0
20
17
25
21
ns
tw Minimum Pulse Width,
Clock
4.5
6.0
16
14
20
17
ns
tw Minimum Pulse Width,
Reset
4.5
6.0
16
14
20
17
ns
tr, tf Maximum Input Rise
and Fall Times
4.5
6.0
500
400
500
400
ns



TRUTH TABLE

RST CS DBX SNKX SRCX
0 X X OPEN OPEN
1 0 0 OPEN OPEN
1 0 1 CNDx VBIASx
1 1 X UNCHANGED UNCHANGED

DOWNLOAD/PRINTOUT
Download or printout an Online Brochure in .pdf format.
LPS SNKQI & SRCQI.pdf


Back to products

RS232DISNKQI & SRCQIDIGINQI64IN-VME64OUT-VME

 


Copyright © 2004 Laser Photo-Tooling Services Incorporated
All Rights Reserved.